Intake Valves

Operation

Installed at the compressor inlet, Air-Con Intake Valves control compressor capacity. At start-up the valve stays open until a control signal is applied to close the valve and restrict the flow.
During normal operation, the valve opens and closes in response to a control signal to meet the downstream air demands.
At shut down, a built-in check valve stays closed to prevent back flow through the compressor.

 

Design Features

  • Straight through design for low pressure drop
  • TFE valve seat for tight seal
  • Viton™ O-Rings for lubricant compatibility
  • One piece housing
  • Side ports for pressure taps
  • Operating pressure 175 psi
  • Sizes 1¾", 2½", 3", 4" and 6"
  • Flows to 1000 scfm